Products Description
With an IP67 protection rating and a mechanical life of no less than 10,000 operations, its high level of integration and reliability makes it a key device for enhancing grid intelligence and improving user experience. The automatic circuit recloser uses vacuum as the arc-extinguishing medium, while the insulation system adopts a combination of solid epoxy resin and air, resulting in excellent insulation performance.
The rated short-time power-frequency withstand voltage to ground, phase-to-phase, and across the contacts is 50 kV, and the rated lightning impulse withstand voltage (peak) to ground, phase-to-phase, and across the contacts reaches 110 kV. Partial discharge is ≤ 10 pC under a test voltage of 1.2 Ur/√3, effectively resisting grid overvoltage and partial discharge risks and ensuring stable operation in complex voltage environments.
The core performance parameters are outstanding. The recloser has a rated current of 630 A, meeting the power transmission requirements of medium- and high-voltage distribution networks.
It features a rated short-circuit making current (peak) of 31.5 kA and a rated short-time withstand current of 12.5 kA for 3 seconds. It can respond rapidly to short-circuit faults, reliably make and withstand fault currents, and, when combined with the automatic reclosing function, promptly restore power supply and reduce outage losses.

The automatic circuit recloser has a compact overall structure and stable operating performance, allowing it to adapt to diverse and complex outdoor environments without frequent maintenance. It maintains excellent operating conditions even in harsh environments such as high temperatures, high humidity, dust, rain, and snow. The recloser is widely applied in intelligent substations, urban medium- and high-voltage distribution networks, industrial park distribution systems, new energy power plant grid-connection projects, and rural power grid upgrading and renovation projects. It meets the protection and control requirements of traditional distribution networks while fully aligning with the automation and integration trends of smart grids, providing strong technical support for the safe, efficient, and continuous operation of power systems.
Main Technical Parameters
|
No. |
Parameter |
Standard Parameter Value |
|
1 |
Rated System Voltage |
13.8kV |
|
2 |
Rated Voltage |
15.5kV |
|
3 |
Rated Current |
630A |
|
4 |
Rated Frequency |
60Hz |
|
5 |
Rated Short-circuit Making Current (Peak) |
31.5kA |
|
6 |
Rated Duration of Short-circuit Withstand Current |
3s |
|
7 |
Rated Short-time Withstand Current |
12.5kA |
|
8 |
Rated Short-duration Power-frequency Withstand Voltage (Phase-to-Earth, Phase-to-Phase) |
50kV |
|
9 |
Rated Lightning Impulse Withstand Voltage (Peak) (Phase-to-Earth, Phase-to-Phase) |
110kV |
|
10 |
Rated Short-duration Power-frequency Withstand(Across Open Contacts) |
50kV |
|
11 |
Rated Lightning Impulse Withstand Voltage (Peak) (Across Open Contacts) |
110kV |
|
12 |
Mechanical Life |
10000times |
|
13 |
Partial Discharge Level |
Test voltage: 1.2Ur/√3, Partial discharge: ≤10 pC |
|
14 |
Arc Quenching Medium |
Vacuum |
|
15 |
Insulating Medium |
Solid Epoxy Resin + Air |
|
16 |
Type or Model of Operating Mechanism |
Permanent Magnet, Three-phase Mechanically Interlocked |
|
17 |
Mechanical Life |
≥ 10,000 operations |
|
18 |
Degree of Protection (Enclosure) |
IP67 |
Hot Tags: 15kv automatic circuit recloser, China 15kv automatic circuit recloser manufacturers, suppliers, factory, 15kV Interlocking Recloser, recloser, 24kV Auto Circuit Recloser, 27kV Interlocking Recloser, 27kV Load Break Switch, 27kV Auto Recloser